Our Walk-in Chamber use urethane-foam panels in a stainless steel or galvanized interior skin. This Walk-in Chamber is same construction used for walk-in coolers in restaurants, but of a higher quality.
WALK-IN CHAMBERS
Description
Applications
Walk-in test Chamber is used for various types of testing such as prototype evaluation, research & development testing, production testing, accelerated stress testing, reliability testing, failure analysis, and any other application where environmental simulation is needed.
Features
- Walk-in, Drive-in Type
- Stainless steel interior (or galvanized for savings)
- Painted galvanized steel exterior for long life
- MAP service doors are hinged (no tools or lifting)
- Easy access to components
- Reliable steam generator system for humidity applications
- Sheathed electric heaters for safety and reliability
- Adjustable vanes in supply grille allow directing of airflow as needed
Standards Implemented and met
- GB-2423. 1-89(IEC68-2-1) Test A: Low-Temperature Test
- GB-2423. 2-89(IEC68-2-2) Test B: High-Temperature Test
- GJB360. 8-87(MIL-STD.202F) High-Temperature Operating Life Test
- GBJl50. 3(MIL-STD-810D) High-Temperature Test
- GJBl50. 4(MIL-STD-810D) Low-Temperature Test
- GB2423. 3-93(IEC68-2-3) Test Ca: a method for steady-state damp heat test
- GB2423. 4-93(IEC68-2—30) Test Db: Damp-Heat Alternative Test
- GJBl50. 9-93(MIL-STD-810D) Damp Heat Test
Optional Accessories
- Cable Port: Two sizes of cable port are available: Φ50mm, Φ100mm.
- Double door
- Pass room: Provided to avoid disturbance of atmospheric temperature and humidity while opening the door.
- Floor reinforcement: Can be fixed if heavy specimens placed in the chamber for the test.
- Carry-in inclined platform: Provided below the door to facilitate the moving of specimens in and out through the door.
- Entire ceiling blow-out duct
- The extremely wide air inlet reduces the airflow rate (down to approx.0.5m/s)
- Dehumidifier
- The rotation regenerating dehumidifier (M-300)ensures precise control of low humidity (21℃,23%RH)for electrostatic reliability tests.
- Temperature and humidity recorder
- 100mm width recording paper with 6 dots
- 180mm width recording paper with 12 dots
- Status indication lamp
- Provide to signal chamber status and warnings when normal running, a malfunction running or stand by occurs.
- Water purifier
- Provided to keep the humidifier heater free from scale and ensure the supply of water to humidifier.
- Power socket
- Air-cooled type condense
Specifications
Note:
- We reserve the right to change specifications without prior notice
- Customized sizes and configurations available
Reviews